A 4 body extra-wide upright mortuary refrigerator rated 850 lbs per tier, with self-contained 115V refrigeration and rack loading, built in Johnson City, Tennessee by American Mortuary Coolers; starting at $9,153.01.
Factory assembly: refrigerator box only
Factory assembly covers the refrigerator box only, with casters installed when selected and applicable. Interior shelving installation and setting or installing the compressor/refrigeration unit are not included in factory assembly. This model ships unassembled only. This service definition does not add a factory-assembly option.
Included configuration and loading arrangement
Four front-loading roller tiers; extra-wide cabinet. Insulated cabinet, self-contained refrigeration and four roller tiers. Trays and handling equipment must be checked separately. A selected caster package does not change the number of storage positions or the approved rack capacity.
Dimensions, access and site fit
89 in D x 44 in W x 83.5 in H cabinet without casters; 81 in D x 36 in W x 75.5 in H usable interior. Confirm total configured height with casters and the selected refrigeration package on the factory drawing. Cabinet height, caster wheel diameter, installed caster height and final refrigeration height are different measurements. Confirm the complete installed envelope, door swing, receiving route, service access and required airflow before ordering.
Confirm tray width/length, usable door opening, clear tier height and lifting-equipment reach for the actual rack layout. Advertised capacity is a position count, not proof that every case or tray fits. Use only the working-load limit confirmed for the exact rack, tray and cabinet configuration; the lowest-rated component governs. Do not drill outside confirmed reinforcement or change tier positions without approval.
Installation and commissioning responsibilities
For an unassembled order, assemble and level the box first. For a factory-assembled box, inspect and position the box, then complete the interior installation and refrigeration placement/setup separately. Install and secure the shelves or roller tiers, check doors and gaskets, and follow the exact equipment instructions for power, airflow, condensate and controls. Factory assembly is not turnkey installation or commissioning.
A factory-packaged refrigeration unit may be factory-built, charged and tested without being mounted on the cabinet. Confirm the exact supplied package; use its nameplate and current instructions for power, clearances, condensate handling and startup. A cabinet-wall air gap is not a substitute for refrigeration airflow and service clearance. Use the required clearances for the supplied equipment rather than a universal overhead allowance.
Startup, everyday use and maintenance
Do not load before installation is complete. Verify empty-unit temperature performance for the period and setpoint specified in the exact startup instructions, record the results, and check the temperature with an independent thermometer. Keep airflow paths open, close doors promptly and do not exceed the approved tray, rack or handling-equipment ratings.
Follow the exact model and refrigeration maintenance instructions. Keep records of model/serial numbers, startup readings, temperature checks, gasket and door condition, cleaning and service. Disconnect power as instructed before cleaning or service; refrigeration and electrical work require appropriately qualified personnel.
Bariatric-capable 4-cadaver upright, extra-wide cabinet clearance, rack limits confirmed for the exact four-position configuration, rack-loading, self-contained 115V refrigeration, built in Johnson City, Tennessee.
At a glance
-
4-body capacity: bariatric-width cabinet
-
Rack working load: confirm the current factory rating: full bariatric case envelope
-
Upright rack-loading design
-
Modular insulated cabinet, 4″ urethane core
-
Self-contained refrigeration: 115V single-phase, NEMA 5-20R plug
-
NSF, UL, ASTM E84 certified · 15-year structural panel warranty · made in the USA
Form AMC-OM-4BX Rev. A · Last updated January 15, 2026 · PDF
AMC 4BX 4-Body Bariatric Upright Mortuary Refrigerator User Manual
Dimensions, assembly, refrigeration start-up, operation, cleaning, maintenance and warranty for the 4BX.
Download the User Manual (PDF)
All equipment manuals
Physical Dimensions
| Exterior (No Casters) |
89"D × 44"W × 83.5"H |
| Exterior (With Casters) |
89"D × 44"W × 91"H |
| Exterior (Casters + Cooling Unit) |
89"D × 44"W cabinet footprint; final installed height requires the current factory drawing. |
| Interior Usable Space |
81"D × 36"W × 75.5"H |
| Loading Method |
Front door upright loading |
| Capacity |
4 bodies, one per tier |
Specifications
| Body capacity |
4 cadavers, bariatric-width clearance |
| Cabinet construction |
Modular insulated, 4″ urethane core |
| Refrigeration |
Self-contained |
| Operating range |
34–40°F body holding |
| Required air clearance |
1″–1.5″ around entire cabinet · package-specific refrigeration clearances, see VC-1.1
|
| Weight per tier |
Confirm the exact rack nameplate and factory rating before loading |
| Gross ship weight |
1,700 lbs (freight, liftgate delivery included) |
| Voltage |
115V / 1-phase / 60 Hz · 4.6 A · NEMA 5-20R plug |
| Certifications |
NSF, UL, ASTM E84 Class A, Prop 65 |
| Warranty |
15-year panel structural, see Warranty Policy (WR-1.0)
|
| Country of origin |
United States, Johnson City, Tennessee
|
| Manufacturer |
American Mortuary Coolers |
Electrical & Compressor Specifications
Amperage
4.6 A
115V · 1-phase · 60 Hz
Plug Type
NEMA 5-20R
Cord & plug supplied
| Supply voltage |
115V / 1-phase / 60 Hz |
| Unit amps (running) |
4.6 A |
| Minimum circuit ampacity (MCA) |
15.0 A |
| Max overcurrent protection (MOPD) |
15 A fuse / breaker |
| Cord & plug |
Supplied from factory, NEMA 5-20R |
| Compressor system capacity |
2,900 BTU/h @ 95°F ambient · 35°F box |
| Refrigerant |
A2L |
| Defrost |
Air defrost |
| Evaporator fan motor |
2-speed EC · 250 CFM |
| Efficiency (AWEF) |
5.61, meets DOE minimum |
| Refrigeration unit size |
16.75″ H × 28.56″ W × 29.75″ D on a 4″ plenum (20.75″ installed) · 115 lb package |
| Compressor service clearance |
the overhead and side clearances required by the exact refrigeration package |
| Listing |
UL listed, US & Canada |
| Refrigeration platform |
Heatcraft Climate Control PRO³, factory electrical spec sheet (PT0032MANAPNA)
|
Plug-and-play on a dedicated 115V / 20-amp circuit, no hard-wiring required. A stamped electrical schedule ships with every quote.
Required Air Clearance & Owner Maintenance, Policy VC-1.1
Standard on all AMC drop-in refrigeration systems. These are conditions of warranty coverage, not recommendations.
-
1″–1.5″ minimum air gap around the entire cabinet: all sides and rear, maintained permanently.
-
the overhead and side clearances required by the exact refrigeration package / condensing unit for airflow, heat rejection, and service access.
- No shelving, cabinetry, soffits, dropped ceilings, boxed enclosures, adjacent equipment, or stored goods may encroach on either envelope.
Owner Maintenance Responsibility
The customer is responsible for ongoing maintenance of the compressor and refrigeration system, including annual professional service as needed: coil cleaning, drain-line clearing, gasket inspection, and verification of refrigerant charge and temperature performance. Routine maintenance, consumables, labor, and service calls are not warranty items.
Published exterior dimensions do not include required clearance, add it when planning your space. Full terms: Ventilation & Clearance Policy (VC-1.1) · Warranty Policy (WR-1.0) · Upright Refrigeration Warranty Claims (RW-1.0) · Ambient Temperature & Refrigeration Sizing (AT-1.0)
Adjustable tier mounting
Each roller tier in the 4BX is a frame that rests on angle channels, and each channel is held by four screws driven directly into the refrigerator wall. The 4BX includes four roller tiers for installation on site. Because the channels are fastened rather than welded, a tier can be placed anywhere the wall is reinforced and moved to a new height later if your trays, lift or staff need it.
The tier channel mounting guide shows the layout step by step. You can also download the one-page Tier Channel Mounting Quick Sheet (PDF), which is page 11 of the 4BX user manual. For sizing help, see the 4-body refrigerator guide.
Standard design features
-
Self-contained condensing unit. The compressor, condenser and evaporator come as one factory-packaged unit for mounting on the cabinet. Setting or installing this refrigeration unit is not included in refrigerator-box factory assembly.
-
Digital thermometer and temperature controller. A digital display shows the box temperature at a glance, and the controller holds the setpoint you choose for body holding.
Doors, casters and refrigeration
-
6″ heavy-duty plated casters. Add a set of four casters to make the cabinet mobile: two locking and two non-locking. Reposition only as permitted by the equipment manual and the approved total load. Engage the specified brakes when the equipment is positioned; caster ratings do not authorize movement while loaded.
-
Chrome-plated lockable door handle. A standard handle is included. Add the chrome-plated lockable handle to keep the refrigerator closed to everyone except authorized staff.
-
Magnetic gasketed door seal. The insulated door closes against a magnetic gasket that seals the whole door edge, which keeps cold air in and holds 34–40°F after the door is opened. Clean and inspect the gasket weekly with mild soap and water.
-
Energy-compliant refrigeration. The self-contained drop-in refrigeration system uses A2L refrigerant and meets current DOE/EPA efficiency rules. Standard units are sized for a conditioned room, and upgrade levels are available for warmer rooms.
Ambient Room Temperature & Refrigeration Sizing, Read Before You Order
The temperature of the room around your refrigerator matters as much as the refrigerator itself. Every refrigeration system rejects heat into that room. The hotter the room, the longer the compressor runs, and the harder it is to hold a steady 34–40°F. Standard refrigeration is sized for a conditioned, ventilated indoor room. If your space runs warm, upsize the refrigeration when you order. It costs far less than a struggling system, temperature swings, or a warranty claim later.
Why ambient temperature is critical
-
Holding temperature: an undersized system in a hot room cannot recover after each door opening, so box temperature drifts above 40°F.
-
Compressor life: long, continuous run times in high heat wear out the compressor and fans early.
-
Condensation & humidity: warm, humid rooms produce more condensate. Connect the drain line, and route it to the external drain or a condensate pump.
-
Warranty: incorrect sizing, installation or placement voids the warranty. Choose the level that matches your hottest conditions, not your average.
How to choose
- Measure the room where the refrigerator will sit at the hottest time of day in the hottest month, not when the HVAC is running at its best.
- Account for heat from nearby equipment, sun-facing walls, bay doors and how often the refrigerator is opened.
- Keep the required clearances: 1″–1.5″ around the cabinet and the overhead and side clearances required by the exact refrigeration package. A blocked compressor behaves like a hot room.
- Install indoors only. Unconditioned garages, mechanical rooms and rooms next to crematory retorts need a review before ordering, call 1-888-792-9315.
If the room runs warmer than 75°F, choose a Refrigeration Upsize option above. Full terms: Ventilation & Clearance Policy (VC-1.1) · Warranty Policy (WR-1.0) · Upright Refrigeration Warranty Claims (RW-1.0) · Ambient Temperature & Refrigeration Sizing (AT-1.0)
Important, Read Before Startup: 2026 Packaged Refrigeration System
Due to the changing refrigerant models under new Freon regulations and updated guidelines, it is critical that you completely read all startup instructions before using your packaged refrigeration system. Please be sure you understand your startup settings and the proper overflow and humidity drainage ports, which require hose adapters.
Condensation Drain Requirement
All 2026 Heatcraft compressors require a drain hose attached to the drain port for condensation, to maximize energy efficiency. Connect the supplied drain line to the drain port before startup.
External Drain Connection
In high-humidity environments or during continuous heavy run-times, the unit may experience overflow. To prevent this, the indoor unit is equipped with a 3/4″ NPT external drain connection that can be routed to an external drain line or a field-supplied condensate pump.
Internal Re-Evaporation
Indoor PRO³ models include a hot-gas re-evaporation pan beneath the compressor, which uses hot refrigerant gas to evaporate condensation naturally during normal operation.
2026 and Forward, Heatcraft PRO³
2026 and later packaged Heatcraft PRO³ systems include many new features made possible by an extremely high-efficiency process. Reviewing the startup documentation ensures these systems perform as designed.
American Mortuary Coolers accepts no liability or responsibility for a customer’s failure to properly start up the new AW2 fully packaged, plug-in refrigeration units. If you have specific questions regarding functions and operations, please reach out prior to ordering.
Full startup manuals and tech bulletins: Packaged Refrigeration Manuals & Startup Guide
Questions before you order? Call 1-888-792-9315 or email [email protected].
Sizing, bariatric clearance & cot compatibility
The 4-Body Extra Wide is the bariatric-capable step up from the 3-Body Extra-Wide Side-Load, built for funeral home consolidations, mid-size hospital morgues, and coroner offices handling recurring bariatric cases. Step up to the 6-Body Dual-Door for higher capacity.
Weight per tier: rated at the factory-confirmed maximum per storage tier: the full bariatric case envelope across all four positions. This is the right call when bariatric is recurring rather than occasional and walk-in floor area isn’t available. The compact 4-body 2-door at the same capacity tier carries a 600 lbs per tier standard-width rating.
Confirm the actual case and tray dimensions, clear door opening, usable tier spacing and approved rack/tray working load before accepting a case. An extra-wide or bariatric designation does not guarantee that every case fits.
Cot and tray compatibility: pairs with the 1000E Bariatric Cot and Double Width Removal Tray. Vertical transfer with the 1,000-lb Hydraulic Scissor Lift.
Background: capacity planning guide. Catalogs: bariatric refrigerators · extra-wide refrigerators.
State-by-state availability & shipping
Gross ship weight 1,700 lbs with liftgate delivery included.
Alabama · Arizona · Arkansas · California · Colorado · Florida · Georgia · Illinois · Indiana · Iowa · Kentucky · Louisiana · Maryland · Michigan · Minnesota · Mississippi · Missouri · North Carolina · Ohio · Oklahoma · Pennsylvania · South Carolina · Tennessee · Texas · Utah · Virginia · Washington · Wisconsin
Financing & planning guides
-
0% financing at checkout: Shop Pay Installments
-
Extended financing on orders over $5,000, apply here
-
Section 179 in-year tax treatment
Frequently asked questions
What is the weight limit per tier?
the factory-confirmed maximum per storage tier, bariatric-rated across all four positions. Standard 4-body uprights are rated at 600 lbs per tier.
What is the gross ship weight?
1,700 lbs gross. Liftgate delivery included from Johnson City, Tennessee.
How much clearance does it need around it?
A minimum 1″ to 1.5″ air gap around the entire cabinet, plus the overhead and side clearances required by the exact refrigeration package. This is standard on all drop-in refrigeration systems and is a condition of warranty coverage, see the Ventilation & Clearance Policy (VC-1.1).
Who is responsible for maintaining the compressor?
The owner. The customer is responsible for ongoing maintenance of the compressor and refrigeration system, including annual professional service as needed. Routine maintenance, cleaning, consumables, and service labor are not warranty items.
What electrical supply does it need?
A dedicated 115V / 20-amp circuit. The unit draws 4.6 running amps and ships with a NEMA 5-20R cord and plug, plug-and-play, no hard-wiring. See the Electrical & Compressor Specifications above.
Do I need a drain line?
In high-humidity or high-temperature environments, yes, attach a hose to the external drain connection and route to a drainage source. See the packaged refrigeration manuals page.
How is the 4-body extra wide different from a standard 4-body?
Extra-wide cabinet for bariatric case clearance and the factory-confirmed rack rating. Standard 4-body uprights can’t accommodate the full bariatric case envelope.
What temperature does it maintain?
34–40°F body holding standard.
Can it be financed?
Yes. 0% Shop Pay Installments. Qualifies for extended financing.
Where is it made?
Johnson City, Tennessee. American Mortuary Coolers, family-owned since 2009, A+ Rated by the Better Business Bureau.
Direct procurement: 1-888-792-9315 · [email protected] · request catalog · dealer inquiries
FREE DOWNLOADS
Maintaining your Model 4BX: free maintenance guide and service log
Every 4-Body Extra-Wide Upright Mortuary Refrigerator ships with a printable two-page AMC Model 4BX 4-Body Extra-Wide Upright Mortuary Refrigerator maintenance guide and service log (PDF). Page one is a daily, weekly, monthly, quarterly and annual upright mortuary refrigerator maintenance checklist written for the top-mounted self-contained refrigeration unit, the door gasket and the roller tiers, with the warranty conditions that apply to this model and a compliance summary of its lower-GWP refrigerant and current DOE and EPA rules. Page two is a quarterly maintenance log, a service and repair record and a notes section to keep with the unit.
Download the 4BX maintenance guide & service log (PDF)
Cabinet height and caster-added height
The supplied caster drawing shows that casters add 7½ in to the 83½ in cabinet, giving 91 in cabinet height with casters before refrigeration. With that drawing’s 16¾ in refrigeration package the component sum is 107¾ in; the drawing labels 108 in nominal overall. The separate no-caster drawing has a 20 in refrigeration package and 103½ in overall. Do not mix those refrigeration revisions. Confirm the final order drawing and required service clearance.
Refrigeration ships separately
The included compressor/refrigeration package ships loose on its own pallet, separate from the cabinet, to simplify customer-managed placement and installation. It does not arrive set on the cabinet as part of factory box assembly. Factory assembly, where selected and offered, covers the refrigerator box and applicable selected casters only. Interior shelving installation and compressor placement/setup are excluded. Arrange suitable unloading and lifting equipment, follow the exact refrigeration instructions, and use qualified personnel for required electrical or refrigerant work.
Compare the related freezer family
Compare the 4-Body Upright Freezer when considering a mortuary freezer rather than a regular mortuary refrigerator. Check the exact temperature rating, cabinet width, loading arrangement, utilities and drawing for each model; a shared body count or room footprint does not make the equipment or its parts interchangeable.
Model-specific parts and service
Use the 4BX parts and service entry and the replacement-parts planning guide to identify parts offered for this exact equipment. Provide model, serial number, year and component photographs before ordering. Cabinet doors, gaskets and shelving components must be matched separately from external rack and lift parts; no cross-model or other-brand fit is implied. Unlisted replacements require a confirmed match rather than a nearest-looking substitute.